Journal of the Korea Institute of Military Science and Technology 2019;22(1):60-71.
DOI: https://doi.org/10.9766/KIMST.2019.22.1.060   
Development of Performance Analysis 80 kW High-efficiency Permanent Magnet Generator for Radar System Power Supply
Ji-Ho Ryu, Chong-Hyeon Cho, Min-Kil Chong, Sung-Jin Park, Kwang-Hee Kang
1Research & Development Center, SUNTECH CO., LTD
2Radar Research & Development Center, LIG Nex1 CO., LTD
3Future Technology Lab., LIG Nex1 CO., LTD
레이더 체계 전원공급용 80 kW급 고효율 영구자석형 발전기 개발 및 성능분석
유지호, 조종현, 정민길, 박성진, 강광희
1(주)썬테크 기업부설연구소
2LIG넥스원(주) 감시정찰연구소
3LIG넥스원(주) 미래기술연구소
Abstract
Electrical power supply is needed to operate the radar system in the field. In addition, it should not cause performance deterioration under the environmental factors due to characteristics of military equipment, and should not cause malfunction due to electromagnetic waves generated in radar, and then should not cause malfunction in radar equipment. Therefore, By applying a permanent magnet to the rotor of the generator, light weighting and high efficiency of generator were achieved. As a result, electrical performance test of the generator, the rated output power was 80.8 kW, the maximum output power was 88.1 kW, and the output power efficiency was 98.1 % under the full load condition. When the load capacity of the generator was changed from no load to full load, the maximum voltage variation was 3.6 % and the frequency variation was 0.3 %. As a result of the transient response test for measuring the output power of the generator according to the load characteristics change, the maximum voltage variation of 7.9 %, frequency variation of 0.5 % were confirmed, and the transient response time was 2.1 seconds. Environmental tests were conducted in accordance with MIL-STD-810G and MIL-STD-461F to evaluate the operability of the generator groups. Normal operation of radar system generator group was confirmed under high temperature and low temperature environment conditions. Electromagnetic tests were conducted to check if electromagnetic wave generated from both radar system and generator group in operation caused any performance deterioration to each other. As a result, it was confirmed that the performance deterioration due to electromagnetic wave inflow, radiation, and conduction did not occur. It is expected that it should be possible to provide high efficiency power supply and stable power supply by applying to various military system as well as radar system.
Key Words: Military Generator, Permanent Magnet Generator, High-efficiency Generator, Environmental Test, EMC(Electro Magnetic Compatibility)


ABOUT
ARTICLE CATEGORY

Browse all articles >

BROWSE ARTICLES
FOR CONTRIBUTORS
Editorial Office
160 Bugyuseong-daero 488beon-gil, Yuseong-gu, Daejeon 34060, Korea
Tel: +82-42-823-4603    Fax: +82-42-823-4605    E-mail: kimst@kimst.or.kr                

Copyright © 2024 by The Korea Institute of Military Science and Technology.

Developed in M2PI

Close layer
prev next