Boresight process is to match the misalignment between PNU(Position Navigation Unit) and the reference axis of K-MLRS cage. It is important process to ensure accuracy of K-MLRS. When PNU is removed from cage in the previous alignment procedure, there is a misalignment angle with cage of K-MLRS during reassembly process. Therefore, boresight process is always need to align reference axes between PNU and K-MLRS cage. However, this study has proposed the case alignment process that it enable to correspond to reference axes between ISA (Inertial Sensor Assembly) block and PNU case. So, improved alignment procedure enables to install PNU in the reassembly process without additional boresight process.