A Study on the Field of View of the Remote FTIR Chemical Imaging Detection System |
Jong-Min Lee, Young-Il Kang, Ju-Hyun Kim |
The 5th Research and Development Institute, Agency for Defense Development |
원거리 화학영상탐지시스템의 시야각에 대한 연구 |
이종민, 강영일, 김주현 |
국방과학연구소 제5기술연구본부 |
|
Abstract |
Remote fourier transform infrared(FTIR) chemical imaging detection system allows detection and identification of gases in the atmosphere from long distances. In this paper, the appropriate field of view(FOV) of the FTIR imaging system was examined and the main performance of the system for the interferometer was described. For the determination of the FOV, simulations of gas dispersion range were performed with the NBC reporting and modeling software(NBC-RAMS) developed by ADD. As a result, minimum 192 mrad of FOV was required for the remote FTIR imaging system to visualize chemical warfare agents dispersed in several hundred meters. At the same time, 0.75 mrad of instantaneous field of view(IFOV) for a linear interferometer proper to take a FOV for the chemical agent imaging. |
Key Words:
FTIR Chemical Imaging Detection System, Remote Sensing, Interferometer |
|